Search results for "Partial least squares regression"
showing 10 items of 122 documents
Eco-Friendly Estimation of Heavy Metal Contents in Grapevine Foliage Using In-Field Hyperspectral Data and Multivariate Analysis
2019
Heavy metal monitoring in food-producing ecosystems can play an important role in human health safety. Since they are able to interfere with plants’ physiochemical characteristics, which influence the optical properties of leaves, they can be measured by in-field spectroscopy. In this study, the predictive power of spectroscopic data is examined. Five treatments of heavy metal stress (Cu, Zn, Pb, Cr, and Cd) were applied to grapevine seedlings and hyperspectral data (350−2500 nm), and heavy metal contents were collected based on in-field and laboratory experiments. The partial least squares (PLS) method was used as a feature selection technique, and multiple linear regressions (…
Burned bones forensic investigations employing near infrared spectroscopy
2017
The use of near infrared (NIR) spectroscopy was evaluated, by using chemometric tools, for the study of the environmental impact on burned bones. Spectra of internal and external parts of burned bones, together with sediment samples, were treated by Principal Component Analysis and cluster classification as exploratory techniques to select burned bone samples, less affected by environmental processes, to properly carry out forensic studies. Partial Least Square Discriminant Analysis was used to build a model to classify bone samples based on their burning conditions, providing an efficient and accurate method to discern calcined and carbonized bone. Additionally, Partial Least Square regres…
Infrared microspectroscopic determination of collagen cross-links in articular cartilage
2017
Collagen forms an organized network in articular cartilage to give tensile stiffness to the tissue. Due to its long half-life, collagen is susceptible to cross-links caused by advanced glycation end-products. The current standard method for determination of cross-link concentrations in tissues is the destructive high-performance liquid chromatography (HPLC). The aim of this study was to analyze the cross-link concentrations nondestructively from standard unstained histological articular cartilage sections by using Fourier transform infrared (FTIR) microspectroscopy. Half of the bovine articular cartilage samples ( n = 27 ) were treated with threose to increase the collagen cross-linking whi…
Fourier transform infrared analysis of commercial formulations for Varroa treatment
2017
A comparative study has been carried out between univariate and multivariate calibration strategies for the simultaneous determination of camphor, thymol, menthol and eucalyptol in commercial formulations used for Varroa treatment. Absorbance peak heights of the transmission mid-infrared (MIR) spectra of individual monoterpenes, prepared in dichloromethane, were measured at 1737, 1151, 1022 and 980 cm−1 (corrected with a base-line at 1933 cm−1) for camphor, thymol, menthol and eucalyptol, respectively. Data were processed using the proportional equations approach in univariate mode. For multivariate calibration, partial least squares (PLS) regression based on a classical 42 design for stand…
2020
Background Small sample sizes combined with multiple correlated endpoints pose a major challenge in the statistical analysis of preclinical neurotrauma studies. The standard approach of applying univariate tests on individual response variables has the advantage of simplicity of interpretation, but it fails to account for the covariance/correlation in the data. In contrast, multivariate statistical techniques might more adequately capture the multi-dimensional pathophysiological pattern of neurotrauma and therefore provide increased sensitivity to detect treatment effects. Results We systematically evaluated the performance of univariate ANOVA, Welch’s ANOVA and linear mixed effects models …
Mineral profiles of legumes and fruits through partial least squares energy dispersive X-ray fluorescence
2019
Abstarct Energy dispersive X-ray fluorescence (ED-XRF) has been employed for the determination of mineral elements in 15 varieties of legumes and 14 cherry samples. ED-XRF signals directly obtained from pulverized samples were modelized by partial least squares (PLS) using Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) of a selected number of samples, after microwave assisted acid digestion, as reference data. Models were built to predict the concentration of Al, Ca, Cu, Fe, K, Mg, P, Sr and Zn. Average concentrations predicted were 6, 930, 7, 40, 6400, 990, 2100, 4 and 15 μg g−1 for Al, Ca, Cu, Fe, K, Mg, P, Sr and Zn, respectively with relative errors from 7 till 26%. …
Solid sampling Fourier transform infrared determination of Mancozeb in pesticide formulations
2004
Abstract A series of approaches have been assayed for FTIR determination of Mancozeb in several solid commercial fungicides using different calibration strategies. The simplest procedure was based on the use of the ratio between the absorbance of a characteristic band of Mancozeb and that of a KSCN internal standard measured in the FTIR spectra obtained from KBr pellets. It was employed the quotient between peak height absorbance values at 1525 cm−1 for Mancozeb and 2070 cm−1 for KSCN. In these conditions a precision as relative standard deviation (RSD) of 0.6% and a relative accuracy error of 0.8% (w/w) were found. For complex formulations, containing other compounds with characteristic ab…
PLS-UV spectrophotometric method for the simultaneous determination of paracetamol, acetylsalicylic acid and caffeine in pharmaceutical formulations
1997
A simple and fast analytical procedure is proposed for the simultaneous determination of paracetamol, acetylsalicylic acid and caffeine in pharmaceuticals by means the partial least square treatment of the spectrophotometric absorbance data between 216 and 300 nm, taken at 5 nm intervals. The method involves the use of 8 standard mixtures of the three compounds assayed, considered at two concentration levels, and the measurement of the absorbance of samples in a 20% (v/v) ethanol in water solution previously filtered. In the analysis of real and synthetic samples precise and accurate values were obtained by the aforementioned procedure, providing in all cases variation coefficients and accu…
Multivariate standardisation for non-linear calibration range in the chemiluminescence determination of chromium.
2006
Multivariate standardisation is proposed for the successful chemiluminescence determination of chromium based on luminol-hydrogen peroxide reaction. In an extended concentration range, non-linear calibration model is needed. The studied instrumental situations were different detection cells, instruments, assemblies, time and their possible combinations. Chemiluminescence kinetic registers have been transferred using piecewise direct standardisation (PDS) method. The optimisation of transfer parameters has been carried out based on the prediction residual error criteria. Non-linear principal component regression (NL-PCR) and non-linear partial least square regression (NL-PLS) were chosen for…
Nutritional parameters of commercially available milk samples by FTIR and chemometric techniques
2004
Abstract A chemometric study on the prediction of the main nutritional aspects of milk has been carried out by using fourier transform infrared spectroscopy (FTIR) attenuated total reflectance (ATR) measurements of commercially available milk samples of different types. Whole, semi and skimmed milks, enriched or not with calcium, vitamins or modified by alteration of lipid or sugar composition were considered. After evaluating different strategies for data acquisition and ATR cleaning between samples, hierarchical cluster analysis (HCA) was carried out for classification of samples in order to choose the calibration set. The prediction capabilities of partial least squares (PLS) data treatm…